CTC_MEPPP_Information_Kit_2019

The Mechanical Electrical Plumbing Productivity Pack is the premier content pack on the market today. It was specifically designed for companies who are designing/working in both the mechanical and electrical disciplines. The MEPPP takes the Mechanical and Electrical Productivity Packs and rolls them into one easy-to-use pack that is ready to use right out of the box.

  • Project setup time is decreased by utilizing comprehensive project organization
  • Automatically detects when elements are mistakenly placed on the wrong workset
  • Hosted families have been converted to un-hosted
  • 50 view templates for all view types, including schedules and 100 predefined view filters
  • All family content is fully integrated with extensive schedules & tags
  • Over 225 mechanical details with all Revit linework and annotations
  • User manual includes links to over 7.5 hrs of instructional videos
  • Buit-in formulas to calculate MOCP, FLA, KVA, & more (with overrides provided for each)
  • Parametric Electrical One-line diagrams & feeder schedules in Revit
  • 350 + electrical families with over 200 symbols
  • Electrical clearance areas based on NEC guidelines
  • All family content is fully integrated with extensive schedules & tags

Download the MEPPP Information Kit

Watch Demo video

Download the MEPPP Brochure

Public

Parameters in This Collection

PARAM DATATYPE TAGS
No Lighting Family Type
f4ff2b81-6679-40b3-b816-96d579802a08
FAMILYTYPE Electrical-Lighting
Nominal Cooling Capacity
7f7b497e-c77e-43db-9645-abc10e89ecf8
HVAC_COOLING_LOAD Mechanical-Loads
Nominal Diameter
66b559c2-6f8b-4cfb-8318-f7dc104d5864
LENGTH GTPS_Group
Nominal Heating Capacity
daf362f3-0971-49d1-b421-34748da03747
HVAC_HEATING_LOAD Mechanical-Loads
Nominal Pipe Diameter
a6b8ff19-0c4f-4bd0-b060-0750db59d425
PIPE_SIZE Plumbing
Nominal Plenum Length
c5e8b29f-badf-495c-8c69-740782fbfe36
LENGTH Mechanical-AirTerminal
Nominal Plenum Length Input
b4bd61f6-69bb-4edb-9bbf-6c0b846bfad9
LENGTH Mechanical-AirTerminal
Notes
4910d787-840b-4e63-90de-0235847d1509
TEXT IdentityData
Nozzle Diameter
5f4d3a19-5157-4539-81c1-9492a499ccc8
HVAC_DUCT_SIZE Mechanical-AirTerminal
Nozzle Length
8b8cdb0d-1129-4d84-ac85-92a1acaa909b
LENGTH Mechanical-AirTerminal
Nozzle Qty
f1b165c4-b5bc-49e7-938b-cabadf42c88a
Nozzle Quantity
INTEGER Mechanical-AirTerminal
NPLV
f3feff7f-5e2b-4f75-a824-ea2b4b88594b
Nonstandard Part-Load Value
NUMBER EnergyAnalysis
Number Of Circuits
13fa0c84-81aa-445b-b822-7ca116cdb8a8
INTEGER Electrical-Circuiting
Number of Poles
cec2e9cb-9151-4b72-a3a6-2ebda7e2b2d4
NOOFPOLES Electrical-Circuiting
Number of Poles_integer
f93de72f-57a0-436f-89d8-ed0caaabb79b
INTEGER Electrical-Circuiting
Occupancy Hazard Classification
7a18f2aa-393b-4c72-8b74-b717c4fc9d95
TEXT FireProtection
Occupied Hours
f2d2f4ee-21ce-4000-a32b-900ff444dc9a
NUMBER EnergyAnalysis
OCPD is Circuit Breaker
b91da259-2bdd-4c20-9edf-a5a0a75993e3
Overcurrent Protection Device is Circuit Breaker
YESNO Electrical-Loads
OCPD is Fuse
3d60b9b7-20d3-4c76-84bd-6bccf2d80c6d
Overcurrent Protection Device is Circuit Breaker
YESNO Electrical-Loads
Odor Filter Air PD
e781f306-318b-4f8c-9d2c-e8ce769a3abd
Odor Filter Air Pressure Drop
HVAC_PRESSURE Mechanical
Odor Filter Description
9d732e1e-e33e-456d-a075-2c45bfe527c4
TEXT Mechanical
Odor Filter Module Length
8e6c6314-80bd-4039-8502-eaa75c494dfa
LENGTH Mechanical
Odor Filter Qty
2ea739a7-7f3e-47db-8ee6-48c6387f0418
Odor Filter Quantity
INTEGER Mechanical
Odor Filter Size
dd0b2c18-2620-45ae-a99c-43d549457e8b
TEXT Mechanical
Odor Filter Type
5d2b5563-0a25-4727-9c56-ebbc129a9dd0
TEXT Mechanical