Parameters in This Collection

PARAM DATATYPE TAGS
RowLocation
92e1a920-871e-40c8-9587-814bb0c13a63
TEXT Electrical
SequenceId
a6ec34f7-1257-4d0e-982a-507c5a33245a
Assigns an identification to elements for construction sequencing and scheduling.
TEXT Common
SerialNumber
84de768a-46b5-47c1-8b06-e85abc283ee2
A number showing the position of an item in a series on a manufactured article for the purposes of identification.
TEXT Common
SiteElevation
fedf2a69-4b45-4cd1-9d00-d99ad10892f0
LENGTH EnergyAnalysis
SizeCircuitBreakerStandard
43a0f574-93df-4224-ad15-10111a8f71ce
The standard circuit breaker size based on NEC.
ELECTRICAL_CURRENT Electrical
SourcePanelJumperPosition
da421bf1-c896-4d8a-bd99-ecd0944bd708
TEXT Electrical
SpacingEmbedStudHorizontal
45d7a8e1-ada5-456d-bbab-58840781b400
The spacing between horizontal studs on a structural connection.
LENGTH Structural
SpacingEmbedStudVertical
9bca0384-5775-44fe-9d9c-37a41b0ce0a0
The spacing between vertical studs on a structural connection.
LENGTH Structural
SpeedExhaustFanBlade
505d8b60-15a0-4552-89bc-99d020cb7abf
NUMBER Mechanical
SpeedExhaustFanBladeFailure
8e7505c1-ed2e-49e7-b126-02e7525f1671
Exhaust fan blade speed at failure conditions
NUMBER Mechanical
SpeedExhaustFanMotor
137de0ff-5374-4f6e-83c0-eeb138cd7201
NUMBER Mechanical
SpeedPumpMotor
86b3fb6d-1a3d-47c6-8d1a-7f1cf7e8a25a
Pump motor speed
NUMBER Mechanical
SpeedReturnFanBlade
c4ca9b24-3406-4125-936f-865a05325daa
NUMBER Mechanical
SpeedReturnFanMotor
24c101a2-ecac-48d4-a571-10ce1a6b7acc
NUMBER Mechanical
SpeedSupplyFanBlade
8822934e-4ba9-46de-bd68-3ca7a7b3bd8e
NUMBER Mechanical
SpeedSupplyFanBladeFailure
9d15da78-c3b7-4f4b-ae73-8e922c53df60
Supply fan blade speed at failure conditions
NUMBER Mechanical
SpeedSupplyFanMotor
e4d93f65-31aa-496a-9136-9f2e28ac346f
NUMBER Mechanical
StageCode
a020e652-cec5-4f8f-adce-339c2c3b9df5
Parameter for use in submission title-block info. This has been created as text as it will either denote RIBA work stages (1, 2, 3, 4 etc.) or other systems of identifying project stage (i.e. CD = concept design, DD = detailed design)
TEXT Common
StagesCooling
0bc69f32-ab8b-4841-b8de-5844704c36ca
INTEGER Mechanical
StagesHeating
64c8408c-e400-4566-880c-8b0220bc937e
INTEGER Mechanical
SuiteLocation
f24753bb-1367-43c8-a701-3e158ace1dd0
TEXT Common
SupplyFanDrive
3848358f-6047-4a3a-9000-aca6cc25b37f
TEXT Mechanical
SupplyFanType
e4e0ccb7-e442-4a50-a01d-9216c717dcd7
TEXT Mechanical
SystemServed
6ca50d7f-74d6-4aed-a85a-f75e322d30a3
TEXT Common
TableTopStandAlone
059a7260-2462-47aa-9d93-93e35ac3df89
TEXT Common